Role of Flux Diverters in Reducing AC Loss in a Single-Phase 6.5 MVA HTS Traction Transformer for Chinese High-Speed Train Carrying High-Order Harmonic Currents

Download (1.38 MB)
journal contribution
posted on 2023-03-08, 21:36 authored by W Song, Zhenan JiangZhenan Jiang, M Yazdani-Asrami, M Staines, Rodney BadcockRodney Badcock, J Fang
The traction transformer is a critical electrical component in high-speed-trains, We are currently building a 6,5 MVA superconducting traction transformer which will increase transformer efficiency to 99%, halve the weight, and avoid the fire risk of the conventional transformer system, AC loss from the transformer windings cannot exceed 2 kW to meet both the efficiency and weight targets, There are significant high frequency harmonics, particularly the $13^{\mathrm {th}}$ harmonic at 650 Hz, on the traction side of the transformer, Our previous work has shown the estimated AC loss in the transformer windings almost doubled with the addition of a 650 Hz harmonic current at the 8% level specified, which is not acceptable, Therefore, it is critical to reduce AC loss in the transformer due to high harmonics, In this study, we explored the role of flux diverters positioned at the outer ends of the high voltage (HV) and low voltage (LV) windings in restraining AC loss in the windings carrying high-order harmonic currents below 2 kW, Five different ring-shaped flux diverter designs were modelled in this work, utilizing the previously developed 2D axisymmetric model using the $H$ formulation, Simulations were carried out to study the influence of the phase of the 13th harmonic, either in phase or out of phase with respect to the fundamental current, and of the inclusion of multiple harmonics on the loss, The simulation results show that placing flux diverters near the end of the windings leads to a magnetic flux distribution in the windings with reduced radial field, and hence significantly reduces the loss, Three of the flux diverter designs achieve the loss target by limiting the AC loss to below 2 kW, with a wide/thin design having the minimum weight and a wide/thick design achieving only 6% less loss, despite being almost four times heavier,

History

Preferred citation

Song, W., Jiang, Z., Yazdani-Asrami, M., Staines, M., Badcock, R. A. & Fang, J. (2022). Role of Flux Diverters in Reducing AC Loss in a Single-Phase 6.5 MVA HTS Traction Transformer for Chinese High-Speed Train Carrying High-Order Harmonic Currents. IEEE Access, 10, 69650-69658. https://doi.org/10.1109/ACCESS.2022.3186858

Journal title

IEEE Access

Volume

10

Publication date

2022-01-01

Pagination

69650-69658

Publisher

Institute of Electrical and Electronics Engineers (IEEE)

Publication status

Published

Online publication date

2022-06-27

ISSN

2169-3536

eISSN

2169-3536

Usage metrics

    Journal articles

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC