AC loss simulation in a HTS 3-Phase 1 MVA transformer using H formulation
journal contribution
posted on 2021-04-07, 21:51 authored by W Song, Zhenan JiangZhenan Jiang, X Zhang, M Staines, Rodney BadcockRodney Badcock, J Fang, Y Sogabe, N AmemiyaOne of critical issues for HTS transformers is achieving sufficiently low AC loss in the windings. Therefore, accurate prediction of AC loss is critical for the HTS transformer applications. In this work, we present AC loss simulation results employing the H-formulation for a 1 MVA 3-Phase HTS transformer. The high voltage (HV) windings are composed of 24 double pancakes per phase wound with 4 mm – wide YBCO wire. Each double pancake coil has 38 ¼ turns. The low voltage (LV) windings are 20 turn single-layer solenoid windings wound with 15/5 (15 strands of 5 mm width) Roebel cable per phase. The numerical method was first verified by comparing the numerical and experimental AC loss results for two coil assemblies composed of two and six double pancake coils (DPCs). The numerical AC loss calculated for the transformer was compared with the measured AC loss as well as the numerical result obtained using the minimum magnetic energy variation (MMEV) method. The numerical AC loss result in this work and experimental result as well as the numerical result using MMEV at the rated current agree to within 20%. Further simulations were carried out to explore the dependence of the AC loss on the gap between the turns of the LV winding. The minimum AC loss at rated current in the 1 MVA HTS transformer appears when the gap between turns is approximately 2.1 mm turn gap in the LV winding. This is due to the change of relative heights between the HV and LV windings which results in optimal radial magnetic field cancellation. The same numerical method can be applied to calculate AC loss in larger rating HTS transformers.
© This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
History
Preferred citation
Song, W., Jiang, Z., Zhang, X., Staines, M., Badcock, R. A., Fang, J., Sogabe, Y. & Amemiya, N. (2018). AC loss simulation in a HTS 3-Phase 1 MVA transformer using H formulation. Cryogenics, 94, 14-21. https://doi.org/10.1016/j.cryogenics.2018.07.003Publisher DOI
Journal title
CryogenicsVolume
94Publication date
2018-09-01Pagination
14-21Publisher
Elsevier BVPublication status
PublishedContribution type
ArticleISSN
0011-2275eISSN
1879-2235Language
enUsage metrics
Categories
Keywords
HTS transformerAC lossH-formulationStructured meshEdge elementHomogenization methodScience & TechnologyPhysical SciencesThermodynamicsPhysics, AppliedPhysicsGeneral PhysicsClassical PhysicsInterdisciplinary EngineeringInterdisciplinary Engineering not elsewhere classifiedElectronic and Magnetic Properties of Condensed Matter; SuperconductivityEngineering Instrumentation